NEW INSTRUCTIONS FOR THE SWISS MARKET REGULATION OPair


For the sale of solid fuel products, as of 1 January 2008 it will be obligatory to specify on the ratings plate the compliance with the new limits indicated in annex 4 of the OAPC (Ordinance on Air Pollution Control of the Swiss).
According to this ordinance, the limits of CO and dusts, depending on the products, must comply with the established values, which are:

EN 303-5 or EN 12809

Wood log and coal fired heating stove with manual loading
1 January 2008 CO: Powders: 800 mg/m3 60 mg/m3
1 January 2011 CO: 800 mg/m3 Powders:50 mg/m3

Wood splinter burning heating stove with automatic loading
1 January 2008 CO: Powders: 400 mg/m3 90 mg/m3
1 January 2011 CO: 400 mg/m3 Powders:60 mg/m3

Pellet stove with automatic loading
1 January 2008 CO: Powders: 300 mg/m3 60 mg/m3
1 January 2011 CO: 300 mg/m3 Powders:40 mg/m3

EN 13240
Wood stoves
1 January 2008 CO: Powders: 1500 mg/m3 100 mg/m3
1 January 2011 CO: 1500 mg/m3 Powders:75 mg/m3

EN 14785
Pellet stoves
1 January 2008 CO: Powders: 500 mg/m3 50 mg/m3
1 January 2011 CO: 500 mg/m3 Powders:40 mg/m3

EN 12815
Wood kitchen (air)
1 January 2008 CO: Powders: 3000 mg/m3 110 mg/m3
1 January 2011 CO: 3000 mg/m3 Powders:90 mg/m3

EN 12815
Wood kitchen (water)
1 January 2008 CO: Powders: 3000 mg/m3 150 mg/m3
1 January 2011 CO: 3000 mg/m3 Powders:120 mg/m3

EN 13229
Closed and open fireplaces (inserts, single-pieces, refractory, etc.)
1 January 2008 CO: Powders: 1500 mg/m3 100 mg/m3
1 January 2011 CO: 1500 mg/m3 Powders:75 mg/m3

For yield, the provisions of EN standards are applicable and there are no special restrictions concerning them except for those already required for CE marking.
Also according to this ordinance, the obligation of marking will concern all products starting from 1 January 2008, including those which have already been purchased by a possible importer/distributor, and placed on the market after 31 December 2007.
For further information, please contact the commercial office of our laboratory.